Built to spec
Built to your engineered drawings, survey, and the real site conditions, not a one-size-fits-all approach forced to fit.
Masonry and Restoration Masonry in Caledon cover brick, block, and stone work plus tuckpointing and building-envelope repair on commercial buildings.
Tell us what you need and we’ll get you a quote. Licensed, insured & WSIB-covered · Free, no-obligation quote & on-site assessment.
Licensed, insured & WSIB-covered · Free, no-obligation quote & on-site assessment.
Built to your engineered drawings, survey, and the real site conditions, not a one-size-fits-all approach forced to fit.
Durable materials and methods chosen for the load, traffic, and environment on site.
Send specs, drawings, or photos and get a free, no-obligation site visit and estimate with no guesswork.
Installation and site work completed in accordance with Ontario requirements.
New cavity-wall masonry uses brick, concrete block, stone, ties, flashing, insulation, and drainage as a coordinated enclosure. Repointing replaces deteriorated mortar with a compatible mix and joint profile. Selective unit replacement treats cracked, spalled, displaced, or contaminated masonry. Helical ties, anchors, pins, and localized rebuilding stabilize separated wythes or failed connections when engineered. Lintel, shelf-angle, parapet, chimney, and flashing reconstruction addresses corrosion and water at concentrated interfaces. Cleaning, poultices, and coatings are selected only after substrate trials.
Step 1, Harrowgate builds and repairs masonry in controlled sample areas before broad production. Investigation and mock-ups establish unit removal, joint preparation, compatible mortar, tooling, cleaning, flashing, and anchor work, while temporary stabilization protects loose or displaced assemblies during access and removals.
Step 2, New work starts with coordinated structural, architectural, envelope, and opening details. We verify supports, shelf angles, embeds, control joints, flashing elevations, weeps, ties, lintels, and interfaces before laying units. Masonry is protected from saturation, freezing, contamination, and rapid drying. Units are laid to line and gauge with full joints, reinforcement and anchors are installed at the specified courses, and cavities remain free of mortar obstruction.
Restoration starts with a condition survey, sounding and probes where authorized, material sampling, movement review, and a representative mock-up. Unsafe or loose areas are stabilized before removals. Joints are raked with methods that protect unit edges, replacement units are toothed into sound work, corroded anchors or lintels are addressed to the design, and compatible mortar is placed in compacted layers. Cleaning begins with the least aggressive accepted method. Harrowgate coordinates access, containment, weather protection, and final inspection.
Step 3, Repointing is sequenced so open joints do not expose large wall areas to rain or instability. Mortar is packed in controlled lifts against a clean, properly conditioned joint and tooled at the correct stage. Replacement units are distributed and toothed into sound work, avoiding straight repair seams that concentrate movement.
Step 4, Harrowgate completes masonry and restoration masonry inspection, testing, records, protection, restoration, and turnover under the issued work.
Step 5, Harrowgate completes masonry and restoration masonry inspection, testing, records, protection, restoration, and turnover under the issued work.
Have drawings for masonry and restoration masonry in Caledon? Send them over and we will scope it.
Mortar is selected from investigation, testing where specified, unit type, existing mortar properties, exposure, movement, moisture behaviour, and the restoration design. Harrowgate builds a mock-up for colour, texture, joint profile, cutting method, and curing. We do not default to a high-strength mortar that transfers stress into older brick or stone.
Spalling commonly follows water saturation, freeze-thaw cycling, salt movement, corroding embedded metal, hard incompatible mortar, or failed flashing and joints. Harrowgate traces the moisture and movement path, replaces unsound units, repairs joints, and coordinates lintel, flashing, weep, sealant, and drainage corrections so the repair addresses the cause.
The required depth comes from the restoration specification and accepted mock-up, based on joint width, sound mortar, unit condition, and tooling. Harrowgate removes deteriorated mortar to a consistent sound substrate without widening joints or damaging unit edges, cleans the joint, and installs compatible mortar in compacted lifts.
Masonry continues only under the project’s cold-weather procedure. Harrowgate controls material temperature, substrate condition, enclosure, heat, wind, moisture, and protection in accordance with CSA A371 and the specification. Frozen units, frozen substrate, direct unvented combustion exposure, and uncontrolled temperature swings are not accepted as normal production conditions.
A mock-up proves the proposed unit match, mortar colour and texture, joint preparation, joint profile, cleaning method, workmanship, and interface treatment on the actual building. The owner and consultant review it before broad production. Harrowgate preserves the accepted mock-up as the field quality benchmark for each repair type.
Loose, displaced, or bulging masonry is treated first as a safety and structural condition. Harrowgate establishes exclusion and access controls, stabilizes the area to the engineer’s direction, opens approved investigation locations, and documents anchors, backing, corrosion, cracks, and moisture. Reconstruction then follows the issued structural and envelope repair details.
Project records include surveys, sample and mock-up approvals, product data, mortar batch control, weather and protection logs, concealed-condition photographs, repair quantities, anchor or flashing inspections, and deficiency closeout. Harrowgate organizes records by elevation and repair type so the consultant can verify work that becomes concealed.
Mortar that is harder or less vapour-permeable than the masonry can concentrate stress and moisture in the units. Compatible mortar is selected from the existing assembly, exposure, testing, and repair objective rather than compressive strength alone.
Corroding shelf angles or ties, missing anchors, water and freeze-thaw, foundation movement, cavity obstruction, and displaced wythes can contribute. A bulge requires stability assessment and concealed-condition investigation before units are reset or repointed.
Still have a question about masonry and restoration masonry in Caledon? Ask our team directly.
Commercial and heavy-civil construction delivered for developers, contractors, property managers, and municipalities.
Send drawings, a site plan, or a description of the scope. Harrowgate Group is licensed, insured, and WSIB-covered.
Licensed, Insured & WSIB-Covered, work managed and documented on every job
Tell us what you need and we’ll get you a quote. Licensed, insured & WSIB-covered · Free, no-obligation quote & on-site assessment.
Harrowgate Group provides masonry and restoration masonry, delivered and installed with quote-ready support across Toronto and surrounding Ontario communities.
Companies We've Worked With
Harrowgate Group delivers commercial and heavy-civil construction for developers, contractors, institutions, municipalities, and property groups across Ontario.
Three fields. We reply with the next step.